New

DIATERMO MB 300D HOSPITAL

Availability: 2
Contact For Price

High frequency electrosurgical equipment suitable to deliver current for monopolar cut and coagulated cut (with different levels of coagulation), bipolar cut and coagulation.

TWIN OPERATIVE ACTIVITY

- two output channels for monopolar cutting

- two independent setting and output channels for the most frequent monopolar coagulation

CONTROLLED CUTTING PROCEDURES

- enhanced cutting current for eschar free incision

- cutting current with selectable coagulating property for bleeding controlled dissection

- low capacitance coupling by slow BLEND current for endoscopic procedures

TWIN CONTROLLED COAGULATION PROCEDURES

- SPEEDY coagulation and DEEP coagulation available to two operators

- SPRAY coagulation by hand switch or foot switch controls

EXTENSIVE BIPOLAR FEATURES

- bipolar cutting current with selectable bleeding control

- slow BLEND cutting current

- automatic Start/Stop coagulation functions

SURGEON AND PATIENT TOTAL SAFETY·

- acceptability of contact impedance between patient body and return electrode continuously monitored by Skin Plate Electronic Control (SPEC)

- H.F. leakage currents continuously monitored

- mains fluctuation automatically compensated before delivery of HF power

PERSONALIZED PROCEDURES

- independent choice of coagulation currents and power levels by each of two operators

- up to 10 procedures can be configured and re-called

EXTENSION DRIVER AND INTERLOCK SIGNALS

- driven output connection to external Argon Plasma unit and Smoke Evacuator unit

AUTOMATIC SELF DIAGNOSIS

- automatic diagnostic control of the complete functionality of electronic unit and connected accessories with coded report of failures

SUITABLE IN:

- OUTPATIENT SURGERY

- GENERAL SURGERY

- PAEDIATRIC SURGERY

- PLASTIC SURGERY

- THORAX SURGERY

- VASCULAR SURGERY

- DERMATOLOGY

- ENDOSCOPY

- GASTROENTEROLOGY

- GYNAECOLOGY

- NEUROSURGERY

- ORTHOPEDICS

- OTORHINOLARINGOLOGY

- PNEUMOLOGY

- UROLOGY

- VETERINARY

Technical Specifications

• Maximum out power monopolar pure CUT: 300 W - 300 O

• Maximum out power monopolar cut-coag CUT80%: 250 W - 300 O

• Maximum out power monopolar cut-coag CUT60%: 200 W - 300 O

• Maximum out power monopolar cut-coag CUT40%: 150 W - 300 O

• Maximum out power monopolar cut ENHANCED: 200 W - 500 O 

• Maximum out power monopolar cut-coag BLEND: 200 W - 300 O

• Maximum out power monopolar coag SPEEDY: 100 W - 500 O

• Maximum out power monopolar coag DEEP: 100 W - 200 O

• Maximum out power monopolar coag SPRAY 70 W - 2000 O

• Maximum out power monopolar coag SPRAY ARGON: 70 W - 2000 O

• Maximum out power bipolar CUT 95 W - 150 O

• Maximum out power bipolar cut-coag CUT80%: 95 W - 150 O

• Maximum out power bipolar cut-coag CUT60%: 95 W - 150 O

• Maximum out power bipolar cut-coag CUT40%: 60 W - 150 O

• Maximum out power bipolar cut-coag BLEND: 90 W - 150 O

• Maximum out power bipolar cut-coag BLEND: 70 W - 100 O

• Working frequency monopolar/bipolar: 425 kHz / 525 kHz

• Patient circuit: F

• Selectable input voltage: 115-230 Vac

• Mains frequency: 50-60 Hz

• Electrical input voltage: 1000 VA

• Size WxHxD mm: 470 x 150 x 400

• Weight: 17.5 kgs

• Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control

• Safety: EN60601-1, EN60601-1-2, EN60601-2-2 

• Electrical Class: I CF, MDD 93/42/EC - Class: II b

Standard accessories

• 1 power supply cord 5 m

• 1 two-button handle (autoclavable code 30539)

• 5 two-button handles (cold sterilizable code 30551)

• 1 cable for flat plate (30559)

• 2 HP double water-proof foot switches

• 3 short, general surgery blade electrodes 7 cm

• 3 long, general surgery blade electrodes 16 cm

• 3 short, general surgery ball electrodes Ø 4 mm, 6 cm

• 1 electrode brush

Quantity:
Contact For Price